~V|CYPE INGENIEROS, S.A.|FIEBDC-3/2002|Ejecutar Generador de precios en HTML. Auxiliar.||ANSI| ~K|\2\3\3\2\2\2\2\EUR|3.00\0.00\0.00\\21.00|| ~X||INFORMACION_GENERADOR\Parámetros de configuración del generador de precios\\| ~C|mt01arl030|m³|Arcilla expandida, de 350 kg/m³ de densidad y granulometría comprendida entre 8 y 16 mm, suministrada en sacos.|59.50||3| ~X|mt01arl030|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33f000000000000fc3f333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f01000000000800303120303420303933333333333309409a9999999999f93f010100000000000000000000000000000000000000000000000001000000010b00617263696c6c615f65787001000000000000000000e075400000000000004940009a9999999999b93f01000000010800706c61737469636f0100000000000000000000fc3f0000000000004940009a9999999999b93f\\| ~C|mt04lvc010c|Ud|Ladrillo cerámico hueco doble, para revestir, 24x11,5x9 cm, según UNE-EN 771-1.|0.13||3| ~X|mt04lvc010c|INFORMACION_GENERADOR\#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\\| ~C|mt08aaa010a|m³|Agua.|1.50||3| ~X|mt08aaa010a|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33f0000000000000000333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f000000000101000000000000000000000000000000000000000000000000010000000104006167756101000000000000000000408f400000000000000000009a9999999999b93f00000000\\| ~C|mt09lec020b|m³|Lechada de cemento 1/3 CEM II/B-P 32,5 N.|105.10||3| ~X|mt09lec020b|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33f0000000000000000333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f01000000000800313720303120303152465c001aa53840000000000000f83f0101000000000000000000000000000000000000000000000000010000000107006d6f727465726f01000000000000000000b09d400000000000004940009a9999999999b93f00000000\\| ~C|mt09mcr021g|kg|Adhesivo cementoso normal, C1 según UNE-EN 12004, color gris.|0.35||3| ~X|mt09mcr021g|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33ffca9f1d24d62603f333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f01000000000800313720303920303414ae47e17a14ae3f000000000000f83f01010000000000000000000000000000000000000000000000000000000001000000010800706c61737469636f01000000001b65fd6662ba603f0000000000c07740009a9999999999b93f\\| ~C|mt09mcr070a|kg|Mortero de juntas cementoso con resistencia elevada a la abrasión y absorción de agua reducida, CG2, para junta abierta entre 3 y 15 mm, según UNE-EN 13888.|0.99||3| ~X|mt09mcr070a|INFORMACION_GENERADOR\#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\\| ~C|mt09mif010ca|t|Mortero industrial para albañilería, de cemento, color gris, categoría M-5 (resistencia a compresión 5 N/mm²), suministrado en sacos, según UNE-EN 998-2.|32.25||3| ~X|mt09mif010ca|INFORMACION_GENERADOR\#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\\| ~C|mt14gsa020ce|m²|Geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, con una resistencia a la tracción longitudinal de 1,63 kN/m, una resistencia a la tracción transversal de 2,08 kN/m, una apertura de cono al ensayo de perforación dinámica según UNE-EN ISO 13433 inferior a 27 mm, resistencia CBR a punzonamiento 0,4 kN y una masa superficial de 200 g/m², según UNE-EN 13252.|0.69||3| ~X|mt14gsa020ce|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33f9a9999999999a93f333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f01000000000800313720303220303379e9263108ac8c3f333333333333e33f010100000000000000000000000000000000000000000000000001000000010800706c61737469636f01000000009a9999999999c93f0000000000c0774001cdccccccccbc6c4001000000010800706c61737469636f01000000009a9999999999a93f0000000000c07740010000000000c09240\\| ~C|mt14gsa020dg|m²|Geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, con una resistencia a la tracción longitudinal de 3,45 kN/m, una resistencia a la tracción transversal de 3,45 kN/m, una apertura de cono al ensayo de perforación dinámica según UNE-EN ISO 13433 inferior a 15 mm, resistencia CBR a punzonamiento 0,8 kN y una masa superficial de 300 g/m², según UNE-EN 13252.|1.17||3| ~X|mt14gsa020dg|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33f9a9999999999a93f333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f0100000000080031372030322030331b2fdd240681953f333333333333e33f010100000000000000000000000000000000000000000000000001000000010800706c61737469636f0100000000333333333333d33f0000000000c0774001cdccccccccbc6c4001000000010800706c61737469636f01000000009a9999999999a93f0000000000c07740010000000000c09240\\| ~C|mt15dan010a|m²|Lámina impermeabilizante flexible de PVC-P (fv), de 1,2 mm de espesor, con armadura de velo de fibra de vidrio, según UNE-EN 13956.|7.57||3| ~C|mt15dan020b|m|Perfil colaminado de chapa de acero y PVC-P, plano, para remate de impermeabilización en los extremos de las láminas de PVC-P y en encuentros con elementos verticales.|2.80||3| ~C|mt16pea020b|m²|Panel rígido de poliestireno expandido, según UNE-EN 13163, mecanizado lateral recto, de 20 mm de espesor, resistencia térmica 0,55 m²K/W, conductividad térmica 0,036 W/(mK), para junta de dilatación.|1.34||3| ~X|mt16pea020b|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33ffa7e6abc7493983f333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f01000000000800313720303620303492cb7f48bf7d9d3f333333333333e33f010100000000000000000000000000000000000000000000000001000000010c00706f6c696573746972656e6f0100000000333333333333e33f0000000000c07740010000000000003e4001000000010800706c61737469636f0100000000fa7e6abc7493983f0000000000c07740010000000000c09240\\| ~C|mt16pxa010ab|m²|Panel rígido de poliestireno extruido, según UNE-EN 13164, de superficie lisa y mecanizado lateral a media madera, de 40 mm de espesor, resistencia a compresión >= 300 kPa, resistencia térmica 1,2 m²K/W, conductividad térmica 0,034 W/(mK), Euroclase E de reacción al fuego, con código de designación XPS-EN 13164-T1-CS(10/4)300-DLT(2)5-DS(TH)-WL(T)0,7--FT2.|3.69||3| ~X|mt16pxa010ab|INFORMACION_GENERADOR\#U0001000000000000000000000000000000e83f0000000000000000333333333333e33ffa7e6abc7493983f333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f0100000000080031372030362030347689eaad81adb23f333333333333e33f010100000000000000000000000000000000000000000000000001000000011300706f6c696573746972656e6f5f757273615f31010000000052b81e85eb51f83f0000000000c0774001000000000000434001000000010800706c61737469636f0100000000fa7e6abc7493983f0000000000c07740010000000000c09240\\| ~C|mt18bcr010pAa800|m²|Baldosa cerámica de gres rústico 4/3/-/E, 20x20 cm, 8,00€/m², según UNE-EN 14411.|8.00||3| ~X|mt18bcr010pAa800|INFORMACION_GENERADOR\#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\\| ~C|mt18rcr010a300|m|Rodapié cerámico de gres rústico, 7 cm, 3,00€/m.|3.00||3| ~X|mt18rcr010a300|INFORMACION_GENERADOR\#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\\| ~C|op00pis010||Pistola de aire caliente para soldadura de materiales termoplásticos.|0.00||7| ~C|mo020|h|Oficial 1ª construcción.|17.24||1| ~C|mo023|h|Oficial 1ª solador.|17.24||1| ~C|mo029|h|Oficial 1ª aplicador de láminas impermeabilizantes.|17.24||1| ~C|mo054|h|Oficial 1ª montador de aislamientos.|17.82||1| ~C|mo061|h|Ayudante solador.|16.13||1| ~C|mo067|h|Ayudante aplicador de láminas impermeabilizantes.|16.13||1| ~C|mo101|h|Ayudante montador de aislamientos.|16.13||1| ~C|mo113|h|Peón ordinario construcción.|15.92||1| ~C|%|%|Costes directos complementarios|0.00||0| ~C|QAB012|m²|Cubierta plana transitable, no ventilada, con solado fijo, tipo invertida, pendiente del 1% al 5%, para tráfico peatonal privado, compuesta de: formación de pendientes: arcilla expandida de 350 kg/m³ de densidad, vertida en seco y consolidada en su superficie con lechada de cemento, con espesor medio de 10 cm; capa separadora bajo impermeabilización: geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, (300 g/m²); impermeabilización monocapa no adherida: lámina impermeabilizante flexible de PVC-P (fv), de 1,2 mm de espesor, con armadura de velo de fibra de vidrio, fijada en solapes y bordes mediante soldadura termoplástica; capa separadora bajo aislamiento: geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, (300 g/m²); aislamiento térmico: panel rígido de poliestireno extruido, de superficie lisa y mecanizado lateral a media madera, de 40 mm de espesor, resistencia a compresión >= 300 kPa; capa separadora bajo protección: geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, (200 g/m²); capa de protección: baldosas de gres rústico 4/3/-/E, 20x20 cm colocadas en capa fina con adhesivo cementoso normal, C1 gris, sobre capa de regularización de mortero de cemento, industrial, M-5, rejuntadas con mortero de juntas cementoso con resistencia elevada a la abrasión y absorción de agua reducida, CG2, para junta abierta (entre 3 y 15 mm), con la misma tonalidad de las piezas.|0.00||0| ~T|QAB012|Formación de cubierta plana transitable, no ventilada, con solado fijo, tipo invertida, pendiente del 1% al 5%, para tráfico peatonal privado, compuesta de los siguientes elementos: FORMACIÓN DE PENDIENTES: mediante encintado de limatesas, limahoyas y juntas con maestras de ladrillo cerámico hueco doble y capa de 10 cm de espesor medio a base de arcilla expandida de 350 kg/m³ de densidad, vertida en seco y consolidada en su superficie con lechada de cemento, proporcionando una resistencia a compresión de 1 MPa y con una conductividad térmica de 0,087 W/(mK); acabado con capa de regularización de mortero de cemento, industrial, M-5 de 4 cm de espesor, fratasada y limpia; CAPA SEPARADORA BAJO IMPERMEABILIZACIÓN: geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, con una resistencia a la tracción longitudinal de 3,45 kN/m, una resistencia a la tracción transversal de 3,45 kN/m, una apertura de cono al ensayo de perforación dinámica según UNE-EN ISO 13433 inferior a 15 mm, resistencia CBR a punzonamiento 0,8 kN y una masa superficial de 300 g/m²; IMPERMEABILIZACIÓN: tipo monocapa, no adherida, formada por una lámina impermeabilizante flexible de PVC-P (fv), de 1,2 mm de espesor, con armadura de velo de fibra de vidrio, colocada suelta sobre la capa separadora, fijada en solapes mediante soldadura termoplástica, y en los bordes soldada a perfiles colaminados de chapa y PVC-P; CAPA SEPARADORA BAJO AISLAMIENTO: geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, con una resistencia a la tracción longitudinal de 3,45 kN/m, una resistencia a la tracción transversal de 3,45 kN/m, una apertura de cono al ensayo de perforación dinámica según UNE-EN ISO 13433 inferior a 15 mm, resistencia CBR a punzonamiento 0,8 kN y una masa superficial de 300 g/m²; AISLAMIENTO TÉRMICO: panel rígido de poliestireno extruido, de superficie lisa y mecanizado lateral a media madera, de 40 mm de espesor, resistencia a compresión >= 300 kPa, resistencia térmica 1,2 m²K/W, conductividad térmica 0,034 W/(mK); CAPA SEPARADORA BAJO PROTECCIÓN: geotextil no tejido compuesto por fibras de poliéster unidas por agujeteado, con una resistencia a la tracción longitudinal de 1,63 kN/m, una resistencia a la tracción transversal de 2,08 kN/m, una apertura de cono al ensayo de perforación dinámica según UNE-EN ISO 13433 inferior a 27 mm, resistencia CBR a punzonamiento 0,4 kN y una masa superficial de 200 g/m²; CAPA DE PROTECCIÓN: Pavimento de baldosas de gres rústico 4/0/-/E (pavimentos para tránsito peatonal medio, tipo 4; pavimentos exteriores y pavimentos con requisitos específicos, tipo 3; exterior, tipo -/E), 20x20 cm colocadas en capa fina con adhesivo cementoso normal, C1 sin ninguna característica adicional, color gris, sobre una capa de regularización de mortero de cemento, industrial, M-5, de 4 cm de espesor, rejuntadas con mortero de juntas cementoso con resistencia elevada a la abrasión y absorción de agua reducida, CG2, para junta abierta (entre 3 y 15 mm), con la misma tonalidad de las piezas. Incluso p/p de crucetas de PVC, fajeado de juntas y puntos singulares, formación y sellado de juntas de pavimento y perimetrales, y limpieza final. Incluye: Replanteo de los puntos singulares. Replanteo de las pendientes y trazado de limatesas, limahoyas y juntas. Formación de pendientes mediante encintado de limatesas, limahoyas y juntas con maestras de ladrillo. Relleno de juntas con poliestireno expandido. Vertido en seco de la arcilla expandida hasta alcanzar el nivel de coronación de las maestras, y consolidación con lechada de cemento. Vertido, extendido y regleado del mortero de regularización. Colocación de la capa separadora bajo impermeabilización. Limpieza y preparación de la superficie en la que ha de aplicarse la impermeabilización. Colocación de perfiles de fijación en los bordes. Colocación de la impermeabilización. Colocación de la capa separadora bajo aislamiento. Revisión de la superficie base en la que se realiza la fijación del aislamiento de acuerdo con las exigencias de la técnica a emplear. Corte, ajuste y colocación del aislamiento. Colocación de la capa separadora bajo protección. Vertido, extendido y regleado del material de agarre o nivelación. Replanteo de las juntas del pavimento. Replanteo del pavimento y fajeado de juntas y puntos singulares. Colocación de las baldosas con junta abierta. Sellado de juntas de pavimento y perimetrales. Rejuntado del pavimento. Criterio de medición de proyecto: Superficie medida en proyección horizontal, según documentación gráfica de Proyecto, desde las caras interiores de los antepechos o petos perimetrales que la limitan. Criterio de medición de obra: Se medirá, en proyección horizontal, la superficie realmente ejecutada según especificaciones de Proyecto, desde las caras interiores de los antepechos o petos perimetrales que la limitan. | ~D|QAB012 |mt04lvc010c\\4.000 \mt01arl030\\0.100 \mt09lec020b\\0.010 \mt16pea020b\\0.010 \mt08aaa010a\\0.014 \mt09mif010ca\\0.075 \mt14gsa020dg\\1.050 \mt15dan010a\\1.050 \mt15dan020b\\0.400 \mt14gsa020dg\\1.050 \mt16pxa010ab\\1.050 \mt14gsa020ce\\1.050 \mt08aaa010a\\0.014 \mt09mif010ca\\0.075 \mt09mcr021g\\4.000 \mt18bcr010pAa800\\1.050 \mt18rcr010a300\\0.400 \mt09mcr070a\\0.300 \op00pis010\\1.000 \mo020\\0.333 \mo113\\0.737 \mo029\\0.182 \mo067\\0.182 \mo054\\0.050 \mo101\\0.050 \mo023\\0.404 \mo061\\0.202 \%\\0.020 \| ~C|Q#||Cubiertas|0.00||0| ~D|Q# |QA#\\1.000 \| ~C|QA#||Planas|0.00||0| ~D|QA# |QAB#\\1.000 \| ~C|QAB#||Transitables no ventiladas|0.00||0| ~D|QAB# |QAB012\\0.000 \| ~M|QAB\QAB012|1\1\1\1\|0.000|| ~C|obra##||QAB012|0.00||0| ~D|obra## |Q#\\1.000 \|